1 | Parameter | PV1503A | PV1503B |
1 | Preset working pressure (depending on device type and hose length) | (90 ± 5) bar |
2 | Outlet temperature measured 10 cm from the nozzle | (60 to 70) ℃ |
3 | Impact pressure measured 15 cm from the nozzle at an angle of 90° | (19 ± 2) N |
4 | Nozzle type depending on device manufacturer | Spraying Systems TP2505 EG NIFAB 2506 |
5 | Distance from nozzle to specimen = 15 cm | To be used for paint coatings of any type on plastic and metal on the exterior of the vehicle (requirements according to Technical Supply Specification). |
6 | Distance from nozzle to specimen = 5 cm | | To be used for low-temperature paint coating (e.g. 90 °C) on all substrates, see No. 12 for control limit, paint flakes |
7 | Distance from nozzle to specimen = 2 cm | | To be used for high-temperature paint coating (140°C); control limit and requirement as for No. 6. |
8 | Angle of jet | 45° | 90° |
9 | Duration of spraying | Spraying acc. to Figure 1 | 1 x 20 s, slight swinging movement, even spraying above the point of intersection of the St. Andrew's cross. |
10 | Nozzle alignment | Along the intersecting legs of the St. Andrew's cross | Point of intersection of the St. Andrew's cross on the specimen |
11 | Spray pattern (check of the setting parameters) | Material to be used: Styroform RTM from Stadur-Süd GmbH, procedure according to 3.4.1 |
12 | Control limit | Paint flakes ≥ 3 mm² and an acceptable test result at 15 cm (distance from nozzle to specimen) indicate a test result that is still acceptable. However, the paint adhesion of the specimen must be optimized and the specimen must be resubmitted. |